Prospector

Polyamide (Nylon): Nylon 12

Product Availability Product Description
Trilliant™ HC THC 1410 Natural North America  
UBESTA 3014U Africa & Middle East
Low viscosity (Injection)
UBESTA 3020GX6 Africa & Middle East
Reinforced with glass fiber, conductive
UBESTA 3020U Africa & Middle East
Medium viscosity (Injection, Extrusion)
UBESTA 3020X29L Africa & Middle East
UV stabilized (Extrusion)
UBESTA 3024GC6 Africa & Middle East
Reinforced with glass fiber
UBESTA 3024LU Africa & Middle East
UV stabilized (Injection)
UBESTA 3024NUX Africa & Middle East
Short cycle (Injection)
UBESTA 3024U Africa & Middle East
Medium viscosity (Injection, Extrusion)
UBESTA 3030JFX1 Africa & Middle East
Flexible (Extrusion)
UBESTA 3030JFX3 Africa & Middle East
Flexible (with low migrate plasticizer, Extrusion)
UBESTA 3030JI46 Africa & Middle East
Flexible (with low migrate plasticizer, Extrusion)
UBESTA 3030JI5L Africa & Middle East
Flexible (Extrusion)
UBESTA 3030JI9L Africa & Middle East
Flexible (Extrusion)
UBESTA 3030LUX Africa & Middle East
UV stabilized (Extrusion)
UBESTA 3030UFX1 Africa & Middle East
UV stabilized (Extrusion)
UBESTA 3030XA Africa & Middle East
High viscosity (Extrusion)
UBESTA 3035LU1 Africa & Middle East
UV stabilized (Injection, Extrusion)
VERDANT™ RRPA1216Y North America
VINPOL RRPA1216 is a recycled, unfilled polyamide 12 product. This product is provided in a black color.
VERDANT™ RRPA12Y North America
VERDANT RRPA12Y is a post-industrial-recycled, unfilled, polyamide 12 resin in black color intended for injection molding applications.
VESTAMID® Care ML16 Europe
VESTAMID® Care ML16 is resistant to body fluids and toxicologically safe. Typical application areas for filled VESTAMID Care ML grades include catheters, housing parts, monitoring and imaging devices and durable medical equipment. Advantages at a glance - High impact resistance - Easy processability & colorability - Low sliding friction - High toughness - High abrasion resistance - Density 1.0 g/cc - High dimensional stability - High chemical resistance - Gamma and EtO sterilizable Biocompatibility of VESTAMID® Care ML VESTAMID® Care ML grades were tested on boicompatibility for applications within the body of up to 30 days contact time and comply with USP class VI and ISO 10993 standards.
VESTAMID® Care ML17 Europe
VESTAMID® Care ML17 is resistant to body fluids and toxicologically safe. Typical application areas for filled VESTAMID Care ML grades include catheters, housing parts, monitoring and imaging devices and durable medical equipment. Advantages at a glance - High impact resistance - Easy processability & colorability - Low sliding friction - High toughness - High abrasion resistance - Density 1.0 g/cc - High dimensional stability - High chemical resistance - Gamma and EtO sterilizable Biocompatibility of VESTAMID® Care ML VESTAMID® Care ML grades were tested on biocompatibility for applications within the body of up to 30 days contact time and comply with USP <88> class VI and ISO 10993 standards.
VESTAMID® Care ML18 Europe
VESTAMID® Care ML18 is resistant to body fluids and toxicologically safe. Typical application areas for filled VESTAMID Care ML grades include catheters, housing parts, monitoring and imaging devices and durable medical equipment. Advantages at a glance - High impact resistance - Easy processability & colorability - Low sliding friction - High toughness - High abrasion resistance - Density 1.0 g/cc - High dimensional stability - High chemical resistance - Gamma and EtO sterilizable Biocompatibility of VESTAMID® Care ML VESTAMID® Care ML grades were tested on biocompatibility for applications within the body of up to 30 days contact time and comply with USP <88> class VI and ISO 10993 standards.
VESTAMID® Care ML19 Europe
VESTAMID® Care ML19 is resistant to body fluids and toxicologically safe. Typical application areas for filled VESTAMID Care ML grades include catheters, housing parts, monitoring and imaging devices and durable medical equipment. Advantages at a glance - High impact resistance - Easy processability & colorability - Low sliding friction - High toughness - High abrasion resistance - Density 1.0 g/cc - High dimensional stability - High chemical resistance - Gamma and EtO sterilizable Biocompatibility of VESTAMID® Care ML VESTAMID® Care ML grades were tested on biocompatibilty for applications within the body of up to 30 days contact time and comply with USP <88> class VI and ISO 10993 standards.
VESTAMID® Care ML21 Europe
VESTAMID® Care ML21 is resistant to body fluids and toxicologically safe. Typical application areas for filled VESTAMID Care ML grades include catheters, housing parts, monitoring and imaging devices and durable medical equipment. Advantages at a glance - High impact resistance - Easy processability & colorability - Low sliding friction - High toughness - High abrasion resistance - Density 1.0 g/cc - High dimensional stability - High chemical resistance - Gamma and EtO sterilizable Biocompatibility of VESTAMID® Care ML VESTAMID® Care ML grades were tested on biocompatibility for applications within the body of up to 30 days contact time and comply with USP <88> class VI and ISO 10993 standards.
VESTAMID® Care ML24 Europe
VESTAMID® Care ML24 is resistant to body fluids and toxicologically safe. Typical application areas for filled VESTAMID Care ML grades include catheters, housing parts, monitoring and imaging devices and durable medical equipment. Advantages at a glance - High impact resistance - Easy processability & colorability - Low sliding friction - High toughness - High abrasion resistance - Density 1.0 g/cc - High dimensional stability - High chemical resistance - Gamma and EtO sterilizable Biocompatibility of VESTAMID® Care ML VESTAMID® Care ML grades were tested on biocompatibility for applications within the body of up to 30 days contact time and comply with USP <88> class vi and ISO 10993 standards.
VESTAMID® Care ML67 Europe
VESTAMID® Care ML67 is resistant to body fluids and toxicologically safe. Typical application areas for filled VESTAMID Care ML grades include catheters, housing parts, monitoring and imaging devices and durable medical equipment. Advantages at a glance - High impact resistance - Easy processability & colorability - Low sliding friction - High toughness - High abrasion resistance - Density 1.0 g/cc - High dimensional stability - High chemical resistance - Gamma and EtO sterilizable
VESTAMID® Care ML94 Europe
VESTAMID® Care ML94 is resistant to body fluids and toxicologically safe. Typical application areas for filled VESTAMID® Care ML grades include catheters, housing parts, monitoring and imaging devices and durable medical equipment. Advantages at a glance - High impact resistance - Easy processability & colorability - Low sliding friction - High toughness - High abrasion resistance - Density 1.0 g/cc - High dimensional stability - High chemical resistance - Gamma and EtO sterilizable Biocompatibility of VESTAMID® Care ML VESTAMID® Care ML grades were tested on biocompatibility for applications within the body of up to 30 days contact time and comply with USP <88> class VI and ISO 10993 standards.
VESTAMID® Care ML-GB30 Europe
Microglass bead-filled (30%) PA12 resin for the injection moulding of rigid, low-warpage and dimensionally accurate mouldings VESTAMID® Care ML grades were tested on biocompatibility for applications within the body of up to 30 days contact time and comply with USP <88> class VI and ISO 10993 standards.
VESTAMID® D 16 stabilized Europe
VESTAMID® D16 stabilized is a medium-viscosity Polyamide 612 compound for extrusion and injection moulding of e.g. monofilaments (toothbrush bristles). The material based on PA612 absorbs only small amounts of water. Components made of this material therefore show excellent dimensional stability under changing ambient humidity. Pigmentation may affect values.
VESTAMID® E 40-S3 Europe
VESTAMID® E40-S3 is a PA 12 elastomer consisting of PA 12 segments and softening segments. The material is free of volatile or migrating plasticizer. The VESTAMID® E represent thermoplastic elastomers generically characterized as polyether block copolyamides (PEBA) consisting of PA 12 and polyether segments. VESTAMID® E40-S3 is especially developed for sport shoe soles. It has good impact strength at low temperatures. Pigmentation may affect values.
VESTAMID® E 47-S1 Europe
VESTAMID® E47-S1 is a polyamide 12 elastomer consisting of PA 12 segments and softening segments. The material is free of volatile or migrating plasticizer. The VESTAMID® E represent thermoplastic elastomers generically characterized as polyether block copolyamides (PEBA) consisting of PA 12 and polyether segments. VESTAMID® E47-S1 is especially developed for sport shoe soles. It has good impact strength at low temperatures. Pigmentation may affect values.
VESTAMID® E 47-S3 Europe
VESTAMID® E47-S3 is a PA 12 elastomer consisting of PA12 segments and softening segments. The material is free of volatile or migrating plasticizer. The VESTAMID® E represent thermoplastic elastomers generically characterized as polyether block copolyamides (PEBA) consisting of PA 12 and polyether segments. VESTAMID® E47-S3 is especially developed for sport shoe soles. It has good impact strength at low temperatures. Pigmentation may affect values.
VESTAMID® E 51-S3 BK E70363 Europe
VESTAMID® E51-S3 BK E70363 is a polyamide 12 elastomer consisting of polyamide 12 segments and softening segments. The material is free of volatile or migrating plasticizer. The VESTAMID® E represent thermoplastic elastomers generically characterized as polyether block copolyamides (PEBA) consisting of PA 12 and polyether segments. VESTAMID® E51-S3 BK E70363 has a good impact strength at low temperatures. Pigmentation may affect values.
VESTAMID® E 55-S3 Europe
VESTAMID® E55-S3 is a PA 12 elastomer consisting of PA 12 segments and softening segments. The material is free of volatile or migrating plasticizer. The VESTAMID® E represent thermoplastic elastomers generically characterized as polyether block copolyamides (PEBA) consisting of PA 12 and polyether segments. VESTAMID® E55-S3 is especially developed for sport shoe soles. It has good impact strength at low temperatures. Pigmentation may affect values.
VESTAMID® E 62-S1 Europe
VESTAMID® E62-S1 is a PA 12 elastomer consisting of PA 12 segments and softening segments. The material is free of volatile or migrating plasticizer. The VESTAMID® E represent thermoplastic elastomers generically characterized as polyether block copolyamides (PEBA) consisting of PA 12 and polyether segments. VESTAMID® E62-S1 is especially developed for sport shoe soles. It has good impact strength at low temperatures. Pigmentation may affect values.
VESTAMID® E 62-S3 BK V303579 Europe
VESTAMID® E62-S3 BK V303579 is a PA 12 elastomer consisting of PA 12 segments and softening segments. The material is free of volatile or migrating plasticizer. The VESTAMID® E represent thermoplastic elastomers generically characterized as polyether block copolyamides (PEBA) consisting of PA 12 and polyether segments. VESTAMID® E62-S3 BK V303579 is especially developed for sport shoe soles. It has good impact strength at low temperatures. Pigmentation may affect values.
VESTAMID® E 62-S3 Europe
VESTAMID® E62-S3 is a PA 12 elastomer consisting of PA 12 segments and softening segments. The material is free of volatile or migrating plasticizer. The VESTAMID® E represent thermoplastic elastomers generically characterized as polyether block copolyamides (PEBA) consisting of PA 12 and polyether segments. VESTAMID® E62-S3 is especially developed for sport shoe soles. It has good impact strength at low temperatures. Pigmentation may affect values.
VESTAMID® E X9200 Europe
The VESTAMID® E series represent thermoplastic elastomers generically characterized as polyether block copolyamides (PEBA) consisting of PA 12 and polyether segments. Characteristic properties of VESTAMID® EX9200 are: - Excellent toughness and flexibility even at low temperatures - Absence of plasticizers and therefore no plasticizer migration - Low density - Good chemical resistance - High dimensional stability and constant physical properties at changing environmental humidity due to low moisture absorption Compared with chemically cross-linked elastomers VESTAMID® EX9200 offers the more economically thermoplastic processing. Pigmentation may affect values.
VESTAMID® E X9203 BK E70365 Europe
VESTAMID® EX9203 BK E70365 is a medium viscosity, heat-stabilized polyamide 12 and is prepared with an efficient halogen-free flame retardant. VESTAMID® EX9203 BK E70365 has been developed especially for the extrusion of corrugated tubes and is distinguished by the following characteristics: - high impact strength and flexibility, also at low temperatures, especially good flexural fatigue behavior - softening by non-migrating polyamide elastomer - good dimensional stability and constant mechanical properties at changing ambient humidity due to low water absorption of polyamide 12 - good chemical resistance - good ageing stability Pigmentation may affect values.