Home > Plastics > Materials > Xarec® > Xarec® EA533 - Datasheet

Xarec® EA533 Data Sheet

Syndiotactic Polystyrene

30% Glass Fiber

Supplied by Idemitsu Chemicals

View Complete Data Sheet Search 95000+ Data Sheets
Create Your Free Account!
Product Description
Crystalline Polymers - 30% Glass Filled, Ignition Resistant, Impact Modified Polymer for Electronic and Electrical Applications
General  
Material Status 
  • Commercial: Active
Availability 
  • Asia Pacific
  • Europe
  • North America
Filler / Reinforcement 
  • Glass Fiber, 30% Filler by Weight
Additive 
  • Flame Retardant
  • Impact Modifier
 
Features 
  • Crystalline
  • Flame Retardant
  • Impact Modified
Uses 
  • Electrical/Electronic Applications
Forms 
  • Pellets
Processing Method 
  • Injection Molding
Physical
Nominal Value
Unit
Test Method
Density
g/cm³
ISO 1183/B
Molding Shrinkage
    Internal Method
Across Flow : 0.0787 in
%
 
Flow : 0.0787 in
%
 
Water Absorption 2 (Equilibrium, 73°F, 50% RH)
%
ISO 62
Mechanical
Nominal Value
Unit
Test Method
Tensile Modulus
psi
ISO 527-2
Tensile Stress (Break)
psi
ISO 527-2
Tensile Strain (Break)
%
ISO 527-2
Flexural Modulus
psi
ISO 178
Flexural Strength
psi
ISO 178
Impact
Nominal Value
Unit
Test Method
Charpy Notched Impact Strength (73°F)
ft·lb/in²
ISO 179
Charpy Unnotched Impact Strength (73°F)
ft·lb/in²
ISO 179
Notched Izod Impact Strength (73°F)
ft·lb/in²
ISO 180
Unnotched Izod Impact Strength (73°F)
ft·lb/in²
ISO 180
Thermal
Nominal Value
Unit
Test Method
Heat Deflection Temperature
     
66 psi, Unannealed 3
°F
ISO 75-2/B
264 psi, Unannealed 3
°F
ISO 75-2/A
264 psi, Unannealed 4
°F
ISO 75-2/A
CLTE
    TMA
Flow : -22 to 86°F
in/in/°F
 
Transverse : -22 to 86°F
in/in/°F
 
RTI Elec
°F
UL 746
RTI Imp
°F
UL 746
RTI Str
°F
UL 746
Electrical
Nominal Value
Unit
Test Method
Volume Resistivity
ohm·cm
IEC 60093
Dielectric Strength
V/mil
ASTM D149
Dielectric Constant (1 MHz)
 
IEC 60250
Dissipation Factor
 
IEC 60250
Arc Resistance
 
ASTM D495
Comparative Tracking Index (CTI) 5
 
IEC 60112
High Amp Arc Ignition (HAI)
    UL 746
0.0591 in
 
 
0.118 in
 
 
High Voltage Arc Tracking Rate (HVTR)
 
UL 746
Hot-wire Ignition (HWI)
    UL 746
0.0591 in
 
 
0.118 in
 
 
Flammability
Nominal Value
Unit
Test Method
Flame Rating (0.0591 in)
 
UL 94
Uses
Uses may also be described by the following terms: Electrical Applications, Electronic Applications, Electrical/Electronic Applications, Electrical Sector.
Available Documents
Technical Datasheet (English)
Injection
Nominal Value
Unit
 
Drying Temperature
°F
 
Drying Time
hr
 
Processing (Melt) Temp
°F
 
Mold Temperature
°F
 
Injection Notes
Mold Temperature for maximum gloss and resistance: 130 to 155°C
Notes
1Typical properties: these are not to be construed as specifications.
224 hrs
380°C tool
4150°C tool
5Solution A
 
UL and the UL logo are trademarks of UL LLC © 2014. All Rights Reserved.
The information presented on this datasheet was acquired by UL Prospector from the producer of the material. UL Prospector makes substantial efforts to assure the accuracy of this data. However, UL Prospector assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.