| Product Description | ||||
|
Parylene HT, the newest Parylene commercially available, replaces the alpha hydrogen atom of the N dimer with fluorine. This variant of Parylene is useful in high temperature applications (up to 450°C) and those in which UV stability is requred. Parylene HT also has the lowest coefficient of friction and dielectric constant, and the highest penetrating power of the four variants.
|
||||
| General | ||||
|
Material Status
|
|
|||
|
Availability
|
|
|||
|
Features
|
|
|||
|
Uses
|
|
|||
|
Agency Ratings
|
|
|||
|
RoHS Compliance
|
|
|||
|
Forms
|
|
|||
| Physical |
Nominal Value
|
Unit
|
Test Method
|
|
Density
|
|
g/cm³
|
ASTM D1505 |
|
Water Absorption (24 hr)
|
|
%
|
ASTM D570 |
| Mechanical |
Nominal Value
|
Unit
|
Test Method
|
|
Coefficient of Friction
|
ASTM D1894 | ||
|
vs. Itself - Dynamic
|
|
|
|
|
vs. Itself - Static
|
|
|
|
| Films |
Nominal Value
|
Unit
|
Test Method
|
|
Film Thickness - Tested
|
|
mil
|
|
|
Secant Modulus - MD (2.0 mil)
|
|
psi
|
ASTM D882 |
|
Tensile Strength - MD
|
ASTM D882 | ||
|
Yield, 2.0 mil
|
|
psi
|
|
|
Break, 2.0 mil
|
|
psi
|
|
|
Tensile Elongation - MD
|
ASTM D882 | ||
|
Yield, 2.0 mil
|
|
%
|
|
|
Break, 2.0 mil
|
|
%
|
|
| Hardness |
Nominal Value
|
Unit
|
Test Method
|
|
Rockwell Hardness (R-Scale)
|
|
|
ASTM D785 |
| Thermal |
Nominal Value
|
Unit
|
Test Method
|
|
Melting Temperature
|
|
°F
|
|
|
CLTE - Flow (77°F)
|
|
in/in/°F
|
ASTM D696 |
|
Specific Heat (68°F)
|
|
Btu/lb/°F
|
ASTM C351 |
|
Thermal Conductivity
|
|
Btu·in/hr/ft²/°F
|
ASTM C177 |
| Electrical |
Nominal Value
|
Unit
|
Test Method
|
|
Surface Resistivity
|
|
ohm
|
ASTM D257 |
|
Volume Resistivity
|
|
ohm·cm
|
ASTM D257 |
|
Dielectric Strength (0.00100 in)
|
|
V/mil
|
ASTM D149 |
|
Dielectric Constant
|
ASTM D150 | ||
|
60 Hz
|
|
|
|
|
1 kHz
|
|
|
|
|
1 MHz
|
|
|
|
|
Dissipation Factor
|
ASTM D150 | ||
|
60 Hz
|
|
|
|
|
1 kHz
|
|
|
|
|
1 MHz
|
|
|
|
| Optical |
Nominal Value
|
Unit
|
Test Method
|
|
Refractive Index
|
|
|
ASTM D542 |
| Additional Information | |||
|
Volume Resistivity, ASTM D257, 23°C, 50% RH: 1.9e17 ohm-cm
Surface Resistivity, ASTM D257, 23°C, 50% RH: 5e15 Nitrogen Gas Permeability, ASTM D1434, 25°C: 4.8 cc-mm/m²-d Oxygen Gas Permeability, ASTM D1434, 25°C: 23.5 cc-mm/m²-d Carbon Dioxide Gas Permeability, ASTM D1434, 25°C: 95.4 cc-mm/m²-d Moisture Vapor Transmission, ASTM F1249, 90% RH, 37°C: 0.22 g-mm-m²-d T5 point, Secant Modulus-Temperature Curve, Modulus=690 MPa: 377°C T4 point, Secant Modulus-Temperature Curve, Modulus=70 MPa: >450°C Continuous Service Temperature: 350°C Short-Term Service Temperature: 450°C |
|||
| Related Terminology | |||
|
Product names can be difficult to match. You may have searched any one of these terms to find this product: Parylene HT, Parylene , ParyleneHT, HT, Polyparaxylylene, PPX, SCS
|
|||
| Features | |||
|
Features may also be described by the following terms: Good Adhesion, Good Electrical Properties, Radiation Resistant, Gamma Stable, Gamma Resistant, Radiation Stable, High Heat Resistance, Good UV Resistance, UV Resistant, Ultraviolet Resistant, Ultraviolet Light Resistant.
|
|||
| Uses | |||
|
Uses may also be described by the following terms: Printed Circuit Boards, Medical Applications.
|
|||
| Agency Ratings | |||
|
This plastic material has 1 certifications from the following agencies (the number in parentheses shows the number of certifications for that agency): ISO (1).
|
|||
| Notes |
| 1Typical properties: these are not to be construed as specifications. |