Product Description
Delrin® 127UV is a high viscosity acetal homopolymer with UV stabilizers developed for automotive interior applications. It has improvements in UV aging characteristics and thermal stability over Delrin® 107.
General  
Material Status 
  • Commercial: Active
Availability 
  • Africa & Middle East
  • Asia Pacific
  • Central America
  • Europe
  • Latin America
  • North America
  • South America
Additive 
  • UV Stabilizer
Features 
  • Fatigue Resistant
  • Good Creep Resistance
  • Good Dimensional Stability
  • Good Toughness
  • Good UV Resistance
  • High Impact Resistance
  • High Molecular Weight
  • High Stiffness
  • High Strength
  • High Viscosity
  • Homopolymer
  • Ultrasonic Weldable
Uses 
  • Automotive Interior Parts
  • Cast Film
  • Engineering Parts
  • Sheet
  • Tubing
  • Wire & Cable Applications
RoHS Compliance 
Automotive Specifications 
  •  1
 
Appearance 
  • Natural Color
Forms 
  • Pellets
Processing Method 
  • Cast Film
  • Extrusion
  • Injection Molding
  • Profile Extrusion
  • Sheet Extrusion
Multi-Point Data 
  • Isothermal Stress vs. Strain (ISO 11403-1)
  • Shear Modulus vs. Temperature (ISO 11403-1)
  • Viscosity vs. Shear Rate (ISO 11403-2)
Part Marking Code (ISO 11469)
  • >POM<
Resin ID (ISO 1043)
  • POM
Physical
Nominal Value
Unit
Test Method
Specific Gravity
     
--
 
ASTM D792
--
g/cm³
ISO 1183
Melt Mass-Flow Rate (MFR)
     
190°C/1.05 kg
g/10 min
ASTM D1238
190°C/2.16 kg
g/10 min
ISO 1133
Melt Volume-Flow Rate (MVR) (190°C/2.16 kg)
in³/10min
ISO 1133
Molding Shrinkage
     
Flow: 24 hr, 0.126 in
in/in
ASTM D955
Across Flow: 24 hr, 0.126 in
in/in
ASTM D955
Across Flow: 0.0787 in
%
ISO 294-4
Flow: 0.0787 in
%
ISO 294-4
Water Absorption
    ISO 62
73°F, 24 hr
%
 
Saturation, 73°F
%
 
Equilibrium, 73°F, 50% RH
%
 
Mechanical
Nominal Value
Unit
Test Method
Tensile Modulus
     
73°F 3
psi
ASTM D638
73°F
psi
ISO 527-2
Tensile Strength
     
Yield, -40°F 3
psi
ASTM D638
Yield, 73°F 3
psi
ASTM D638
Yield, 212°F 3
psi
ASTM D638
Yield, 73°F
psi
ISO 527-2
-40°F 3
psi
ASTM D638
73°F 3
psi
ASTM D638
212°F 3
psi
ASTM D638
Tensile Elongation
     
Yield, -40°F 3
%
ASTM D638
Yield, 73°F 3
%
ASTM D638
Yield, 212°F 3
%
ASTM D638
Yield, 73°F
%
ISO 527-2
Break, -40°F 3
%
ASTM D638
Break, 73°F 3
%
ASTM D638
Break, 212°F 3
%
ASTM D638
Break, 73°F
%
ISO 527-2/50
Nominal Tensile Strain at Break (73°F)
%
ISO 527-2
Flexural Modulus
     
-40°F
psi
ASTM D790
73°F
psi
ASTM D790
212°F
psi
ASTM D790
73°F
psi
ISO 178
Impact
Nominal Value
Unit
Test Method
Charpy Notched Impact Strength
    ISO 179/1eA
-22°F
ft·lb/in²
 
73°F
ft·lb/in²
 
Charpy Unnotched Impact Strength
    ISO 179/1eU
-22°F
ft·lb/in²
 
73°F
ft·lb/in²
 
Notched Izod Impact
     
73°F
ft·lb/in
ASTM D256
-40°F
ft·lb/in²
ISO 180/1A
73°F
ft·lb/in²
ISO 180/1A
Unnotched Izod Impact (73°F)
 
ASTM D4812
Hardness
Nominal Value
Unit
Test Method
Rockwell Hardness
     
R-Scale
 
ASTM D785, ISO 2039-2
M-Scale
 
ISO 2039-2
Thermal
Nominal Value
Unit
Test Method
Deflection Temperature Under Load
     
66 psi, Unannealed
°F
ASTM D648
66 psi, Unannealed
°F
ISO 75-2/B
264 psi, Unannealed
°F
ASTM D648
264 psi, Unannealed
°F
ISO 75-2/A
264 psi, Annealed
°F
ISO 75-2/A
Melting Temperature 4
°F
ISO 11357-3, ASTM D3418
CLTE
     
Flow: 73 to 131°F
in/in/°F
ASTM E831, ISO 11359-2
Flow: -40 to 73°F
in/in/°F
ISO 11359-2
Flow: 131 to 212°F
in/in/°F
ISO 11359-2
Transverse: -40 to 73°F
in/in/°F
ISO 11359-2
Transverse: 73 to 131°F
in/in/°F
ISO 11359-2
Transverse: 131 to 212°F
in/in/°F
ISO 11359-2
RTI Elec (0.0331 in)
°F
UL 746
RTI Imp (0.0331 in)
°F
UL 746
RTI Str (0.0331 in)
°F
UL 746
Electrical
Nominal Value
Unit
Test Method
Surface Resistivity
ohm
ASTM D257
Volume Resistivity
     
73°F
ohm·cm
ASTM D257
--
ohm·cm
IEC 60093
Dielectric Constant
     
73°F, 1 MHz
 
ASTM D150
73°F, 100 Hz
 
IEC 60250
73°F, 1 MHz
 
IEC 60250
Dissipation Factor (73°F, 1 MHz)
 
IEC 60250
Comparative Tracking Index
V
IEC 60112
Flammability
Nominal Value
Unit
Test Method
Flame Rating (0.0331 in)
 
UL 94, IEC 60695-11-10, -20
Oxygen Index
%
ISO 4589-2
Related Terminology
This supplier and product may also be known by these terms: DerlinProduct names can be difficult to match. You may have searched any one of these terms to find this product: Delrin® 127UV NC010, Delrin 127UV NC010, Delrin® , Delrin, Delrin127UVNC010, 127 UV NC 010, 127UV NC010, 127UV, UVNC, NC010, 127UVNC010, Acetal Homopolymer, Acetal Homopolymer, Acetal (POM) Homopolymer, Acetal POM Homopolymer, Acetal, pom, DuPont, AcetalPOMHomopolymer, UV127
Features
Features may also be described by the following terms: High Viscosity, Good UV Resistance, UV Resistant, Ultraviolet Resistant, Ultraviolet Light Resistant, Good Toughness, Tough, High Strength, High Molecular Weight, High MW, High Stiffness, Good Dimensional Stability, Dimensionally Stable, Good Creep Resistance, Creep Resistant, High Impact Resistance, Ultrasonic Weldable.
Uses
Uses may also be described by the following terms: Cast Film, Tubing, Tube, Wire and Cable Applications, Wire & Cable Applications, Engineering Parts.
Automotive Specifications
This plastic material has approval for 4 automotive specifications from the following agencies (the number in parentheses shows the number of specifications for that agency): ASTM (1), CHRYSLER (1), GM (1), FORD (1).
Injection
Nominal Value
Unit
 
Drying Temperature
°F
 
Drying Time - Desiccant Dryer
hr
 
Suggested Max Moisture
%
 
Processing (Melt) Temp
°F
 
Melt Temperature, Optimum - Injection Molding
°F
 
Mold Temperature
°F
 
Mold Temperature, Optimum - Injection Molding
°F
 
Drying Recommended
 
 
Notes
1This specification is applicable for the Americas region.
2Typical properties: these are not to be construed as specifications.
30.20 in/min
410°C/min
 
IDES
UL and the UL logo are trademarks of UL LLC © 2013. All Rights Reserved.
The information presented on this datasheet was acquired by UL IDES from the producer of the material. UL IDES makes substantial efforts to assure the accuracy of this data. However, UL IDES assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.