Home > Plastics > Materials > Tarflon™ > Tarflon™ #2200 - Datasheet

Tarflon™ #2200 Datasheet

Polycarbonate

Supplied by Formosa Idemitsu Petrochemical Corporation

View Complete Data Sheet Search 96000+ Data Sheets
Create Your Free Account!
Product Description
FCFC PC resin #2200 meets the requirements of FDA, UL and the certificates of environmental protection.
General  
Material Status 
  • Commercial: Active
Availability 
  • Asia Pacific
Features 
  • Good Dimensional Stability
  • Good Electrical Properties
  • High Clarity
  • High Impact Resistance
  • Medium Viscosity
Uses 
  • Bottles
  • Containers
  • Electrical Parts
  • Kitchenware
  • Medical/Healthcare Applications
UL File Number 
  • 238753
Forms 
  • Pellets
Physical
Nominal Value
Unit
Test Method
Density
g/cm³
ISO 1183
Melt Volume-Flow Rate (MVR) (300°C/1.2 kg)
in³/10min
ISO 1133
Molding Shrinkage - Flow
in/in
ASTM D955
Water Absorption (Saturation, 73°F)
%
ISO 62
Mechanical
Nominal Value
Unit
Test Method
Tensile Modulus
psi
ISO 527-2
Tensile Stress
    ISO 527-2
Yield
psi
 
Break
psi
 
Tensile Strain (Break)
%
ISO 527-2
Flexural Modulus
psi
ISO 178
Flexural Strength
psi
ISO 178
Impact
Nominal Value
Unit
Test Method
Unnotched Izod Impact Strength (73°F)
ft·lb/in²
ISO 180
Hardness
Nominal Value
Unit
Test Method
Rockwell Hardness
    ISO 2039-2
M-Scale
 
 
R-Scale
 
 
Thermal
Nominal Value
Unit
Test Method
Heat Deflection Temperature (264 psi, Unannealed)
°F
ISO 75-2/A
CLTE - Flow
in/in/°F
ASTM D696
Electrical
Nominal Value
Unit
Test Method
Volume Resistivity
ohm·cm
IEC 60093
Electric Strength (0.0394 in)
V/mil
IEC 60243-1
Dielectric Constant
    IEC 60250
100 Hz
 
 
1 MHz
 
 
Dissipation Factor
    IEC 60250
100 Hz
 
 
1 MHz
 
 
Arc Resistance
sec
ASTM D495
Flammability
Nominal Value
Unit
Test Method
Flame Rating
    UL 94
0.118 in
 
 
0.236 in
 
 
0.0142 in
 
 
0.0591 in
 
 
0.114 in
 
 
Optical
Nominal Value
Unit
Test Method
Refractive Index
 
ASTM D542
Transmittance
%
ASTM D1003
Features
Features may also be described by the following terms: High Clarity, Good Dimensional Stability, Dimensionally Stable, Good Electrical Properties, High Impact Resistance, Medium Viscosity.
Uses
Uses may also be described by the following terms: Medical Applications.
Available Documents
Technical Datasheet (English)
Notes
1Typical properties: these are not to be construed as specifications.
 
UL and the UL logo are trademarks of UL LLC © 2014. All Rights Reserved.
The information presented on this datasheet was acquired by UL Prospector from the producer of the material. UL Prospector makes substantial efforts to assure the accuracy of this data. However, UL Prospector assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.